Akari ADC AKTX-101 Hits Urothelial Tumors Resistant to Trodelvy

TAMPA – – October 27, 2026 -- Akari Therapeutics (Nasdaq: AKTX) reported that its TROP2-targeted ADC AKTX-101 slowed tumor growth in urothelial cancer models with limited response to Padcev or acquired resistance to Trodelvy. The company is targeting a Phase 1 start in mid-2027.

AKTX-101 inhibits tumor growth where Padcev shows limited response

In the UM-UC-14 advanced urothelial carcinoma model, which represents metastatic urothelial cancer, AKTX-101 achieved statistically significant tumor growth inhibition versus vehicle. Padcev (enfortumab vedotin), approved as first-line therapy in this setting, had limited responsiveness on the tumor in the same model, according to Akari.

Trodelvy-resistant tumors slow again after switch to PH1 payload

Tumors first treated with Trodelvy (sacituzumab govitecan) developed resistance and resumed growth. When they were switched to AKTX-101, growth slowed again.

Akari Targets Mid-2027 First-in-Human Trial for PH1-Based ADC

TAMPA – October 27, 2026 -- Akari Therapeutics (Nasdaq: AKTX) is targeting a First-In-Human trial of its lead antibody drug conjugate (ADC), AKTX-101, by mid-2027, after starting IND-enabling studies. The company laid out its investment case in the Virtual Investor "Why Now" on-demand conference.

CEO Abizer Gaslightwala argued that now is a pivotal time for Akari. He cited a fast-changing ADC landscape and rising industry demand for differentiated payload technologies.

Akari pitches PH1 splicing payload as alternative to conventional ADC toxins

Akari's proprietary PH1 platform is a spliceosome modulator designed to disrupt RNA splicing inside cancer cells. Current ADCs rely on microtubule inhibitors and DNA-damaging agents. According to the company, PH1 is meant to address limitations of those conventional payloads.

Akari Targets Mid-2027 Phase 1 Start for Splicing-Payload ADC

TAMPA – October 27, 2026 -- Akari Therapeutics (Nasdaq: AKTX) plans to begin Phase 1 clinical development of its lead antibody drug conjugate, AKTX-101, in mid-2027, with the compound now moving through IND-enabling toxicology and safety studies and large-scale GMP manufacturing.

CEO Abizer Gaslightwala laid out the strategy in a new CEO Corner segment. He argues that payload differentiation will matter more as ADCs move into front-line therapy and patients develop resistance to current payload classes, leaving few follow-on options.

MADD Summit Pulls 80 Leaders to Tackle Falling DUI Enforcement

Image
MADD Summit Pulls 80 Leaders to Tackle Falling DUI Enforcement

Hurst, Texas – October 27, 2026 -- Mothers Against Drunk Driving (MADD) convened 80 traffic safety leaders from 38 jurisdictions on November 17–19, 2025, to address declining DUI enforcement capacity across the United States.

Attendees included state police agencies, sheriff's offices, municipal police departments, prosecutors' offices and highway safety organizations. MADD ran the National Law Enforcement Leadership Summit on Impaired Driving as a working session rather than a traditional conference.

Four pressures are eroding DUI enforcement effectiveness

Participants said proactive traffic stops have fallen steadily since the COVID-19 pandemic, cutting officer visibility and deterrence. Staffing shortages and accelerated hiring cycles have left departments with newer officers who have limited experience with complex DUI and drug-impaired investigations.

OPC UA Connection Test Proves Only Part of Historian Data Path

Image
OPC UA Connection Test Proves Only Part of Historian Data Path

Global – October 27, 2026 -- A successful OPC UA connection check shows only that a client can reach the endpoint. It does not prove the intended nodes are readable, monitored, mapped or written to the historian, according to a five-step troubleshooting workflow for industrial data pipelines.

The method starts with one known, changing point, traced from the OPC UA server to one expected historian table. Large tag lists hide the first failure.

OPC UA vs MQTT: Match the Protocol to the Plant Data Role

Image
OPC UA vs MQTT: Match the Protocol to the Plant Data Role

Global – October 27, 2026 -- Industrial data architects should choose OPC UA when a collector must discover and read a structured source, and MQTT when producers publish through a broker to one or more consumers, according to a TDengine technical comparison. The guide adds that the two names do not describe equivalent layers, so the rule is only a starting point.

OPC UA preserves equipment context that MQTT leaves to the architect

OPC UA is a family of specifications covering Client/Server services, information modeling, Alarms and Conditions, Historical Access and PubSub. A server can organize measurements under equipment objects, attach engineering units and ranges, and expose status, timestamps and methods. A client can browse that address space instead of encoding meaning in topic strings.

Not every server delivers a rich model, however. Some expose flat tag lists, incomplete metadata or vendor-specific structures.

OPC UA Historians Need Alarm Records, Not Just Tag History

Image
OPC UA Historians Need Alarm Records, Not Just Tag History

Global – October 27, 2026 -- A pump pressure trend shows when a value left its normal range but cannot show which alarm changed state, what severity the server reported, or when an operator acknowledged it. Those answers sit in separate OPC UA records, and historian designs must decide which questions each record has to answer.

Tag history stores values, not alarm lifecycles

An OPC UA client collects a variable through a monitored item. When DataChange criteria are met, the server sends a DataValue that the historian can store with source timestamp, server timestamp, and StatusCode, depending on the collector mapping. Sampling, deadbands, queues, and timestamp selection determine how much process behavior survives.

Business Jet Adds 70,000 Sq Ft of Hangars at Dallas Love Field

Image
Business Jet Adds 70,000 Sq Ft of Hangars at Dallas Love Field

Dallas – October 27, 2026 -- Business Jet is building two hangars totaling nearly 70,000 square feet at Dallas Love Field (KDAL), lifting its footprint to 475,000 square feet across 19 hangars and 2 executive terminals. Completion of the 18th and 19th hangars is scheduled for January 2026.

New hangars are sized for the largest ultra-long-range jets

The side-by-side hangars have 28-foot doors to fit aircraft such as the Gulfstream G700 and Bombardier Global 7500. Business Jet designed each building for a different tenant profile. One is a build-to-suit space for a single tenant, with custom design and elevated lobby finishes. The other is configured for multiple tenants, with seven individual office and shop spaces.

Both buildings include epoxy-coated floors, LED lighting, large format fans, radiant tube heating and electric vehicle chargers. Integrated utility pedestals supply 208/480/115-amp power, water and compressed air.

Slowest OPC UA Rate That Preserves Process Behavior Is Right

Image
Slowest OPC UA Rate That Preserves Process Behavior Is Right

Global – October 27, 2026 -- The right OPC UA collection rate is the slowest configuration that still preserves the process behavior needed for operations and historical analysis, and it is set across five separate stages rather than one "scan rate." Device updates, server sampling, subscription publishing, filtering and historian storage each have their own timing. Treating them as one setting can add load without adding information, or hide a pressure transient the historian was expected to explain.

Server sampling cannot beat the source update rate

A PLC may update a temperature every 500 milliseconds while the OPC UA server refreshes its internal value once per second. A client request to sample every 100 milliseconds then re-reads the same value or detects changes no sooner than the server exposes them.

OPC UA Mapping: Keep NodeId, Asset Key and Display Name Separate

Image
OPC UA Mapping: Keep NodeId, Asset Key and Display Name Separate

Global – October 27, 2026 -- An OPC UA NodeId tells a client which node to read, but not which pump, line or measurement that node represents in the plant. Reliable mapping therefore keeps source identity, browse path, equipment identity and user-facing label connected but stored as separate fields.

Namespace indexes can change between sessions, so URIs must be stored

A NodeId such as ns=4;s=Pump01.DischargePressure uses 4 as an index into the session's NamespaceArray. The OPC UA specification allows that index to change in a later session. A stored ns=4 string without its namespace URI can point to the wrong namespace after the server's table changes. Mappings should retain the endpoint, namespace URI, identifier type and identifier, and resolve the current index at connection time.