CHICAGO -- November 24, 2026 -- Aviemore Motion Technologies introduced seal-less magnetic coupling pumps for liquid-cooled AI data centers at the SC26 supercomputing conference in Chicago on Nov. 16, supplying pump, motor and drive under a single part number. The platform covers 0.10 to 5.0 kW of output on DC buses from 12 to 800 V, a 50-fold power span by our calculation.
That voltage window takes in the 54 VDC rack power common today and the 800 VDC architecture Aviemore expects in the first commercial systems shipping in Q2 2027.
Aviemore sizes its range against racks that draw 71% more power
Aviemore says AI racks draw 140 kW today, with 240 kW racks close behind and 600 kW to megawatt-class racks in future planning. A 240 kW rack is about 71% above 140 kW, and a 600 kW rack is about 4.3 times it. The company puts the in-rack voltage shift from 54 VDC to 800 VDC, a roughly 15-fold increase.
Because 54 V falls inside the 12 to 800 V range, one pump platform spans both bus generations. CDU builders would not need to qualify a separate part for each.
Magnetic coupling removes the shaft seal from the fluid path
The pumps transmit torque through a magnetic coupling across a non-contact sealed barrier. Aviemore says this leaves no dynamic seal and no wear item in the fluid path, and that the pumps can run dry during commissioning or a loss of prime. A slotless brushless DC motor and integrated drive complete the assembly.
The company says CDU builders source, qualify and service one component instead of three. It describes most data center pumps today as relying on a shaft seal, a bolt-on motor and a third-party drive.
"There is no seal to leak or wear out," said CEO Moe Barani. He says Aviemore can turn a custom change in weeks instead of quarters. The company attributes that speed to doing winding, machining, assembly and test in house.
Three product lines split the 0.10 to 5.0 kW range
- Rack CDU Pumps: 0.10 to 2.0 kW, 12 to 800 V DC, AC and DC drive, for in-rack and sidecar CDUs.
- Row and Facility Pumps: 1.0 to 5.0 kW, 12 to 800 V DC, AC and DC drive, for row CDUs, coolant skids and facility loops.
- OEM Custom Solutions: co-engineered to the customer's architecture, with AC and DC drive options.
The two catalog lines overlap between 1.0 and 2.0 kW. Both offer AC and DC drive options.
Radford, Virginia plant carries all production, with 15,000 motors cited as track record
Aviemore designs and builds the pumps in a 156,000 square foot facility in Radford, Virginia. Its quality system is built on ISO 9001, and the company says products are UL and Intertek certifiable on request. It works with Intertek on testing and certification and with Virginia Tech on research. It also partners with the Virginia Economic Development Partnership and GO Virginia.
The company says its proprietary slotless motor design has shipped in more than 15,000 motors with zero motor defects. It says its team has worked together for more than 25 years and has designed patented pumps for 20 years. According to Aviemore, those pumps remain in service at hyperscale operators, none of which it names. It also says the Radford build supports engineering and manufacturing jobs in Southwest Virginia and that hiring grows with AI demand.
Aviemore did not disclose pricing, shipment dates or customer names.
The company says it is meeting HPC system builders, thermal engineers and CDU manufacturers at SC26 to size pumps for their designs.